My heading is awesome

Lorem ipsum dolor sit amet, at mei dolore tritani repudiandae. In his nemore temporibus consequuntur, vim ad prima vivendum consetetur. Viderer feugiat at pro, mea aperiam

Glove box

VTC-100 compact spin coater is CE certified  and designed for material research lab to make quality sol-gel coating at easy and quick upto 4″ wafer. The spin speed is variable from 500-8000 rpm with two programmable segments. The complete accessories are included for immediate use.

Glove box Model

Compact Stainless Steel Vacuum Glove Box (22″x17″x16″) with Vacuum Flange & Gauge – VGB-1

VGB-1 is a small size stainless steel glove box with  Airlock Chamber, Gauges, and vacuum Flanges, which allows the glove box to vacuum the chamber to remove moisture and oxygen without expensive inert gas purging, It is an ideal tool for material and chemical researchers to process air sensitive materials and solutions.

DesriptionSpecification
Glove Box Chamber- Case Material: Made of 11 gauge (3mm thickness) 304 stainless steel sheet with the support frame, which provides the heavy-duty structure for vacuum
- Dimensions: 555mm(L) x 444mm(W) x 414mm(H)
- Max. Positive Pressure: 810 Torr (1.1 atm)
- Note: Gloves cannot work if pressure is higher than 810 Torr
- Max. Vacuum Level: 1.59E-2 Torr
- ~50 Torr after 5 min pumping
- ~6E-2 Torr after 4 hr pumping.
- Note: Stainless Steel case may deform at a higher vacuum level
- Leakage Rate in GloveBox: < 6 Torr/hour 
- Overall Dimension Drawing   
 Section View Enlarging
Air-lock Chamber- Dimensions: 200mm(ID) x 220mm(L)
Vacuum gauge and valves- Two vacuum flanges are included for the glove box to achieve vacuum to remove moisture and oxygen without expensive inert gas purging.
- Do not operate under vacuum. Vacuum is used for purging the chamber before the operation.
- One KF-25 connector is installed on the back for connecting the humidity monitor or other testing equipment.
On the Glove Box Chamber Dimension On the Air-lock Chamber
Power Extension- One extension socket (Max power 1500W) is installed in the glove box main chamber.
- Note: 110V power cord was included for immediate use. (For 208~240V power supply, no plug will be included) 
Gloves- One pair of Latex Gloves are included for immediate use.
- Optional: You may order 6'' Butadyl® gloves here because they have:
- Increased stretching, bending ability, and tear strength
- High effectiveness when vaporized hydrogen peroxide (VHP) is present
- High resistance to aromatics, hydrocarbons, solvents, fats, and acids
- High static dissipative qualities   
Vacuum pump and Pressure Controller- The vacuum pump and fittings are not included. (Please order separately under Personalization) 
(Optional)- Note: A KF25 Vacuum Right-Angle Valve is necessary for connecting to a vacuum pump, please order it accordingly.
- In order to keep constant pressure of inert gas inside the chamber, you need a pressure controller by click Pic below.
- Pressure controller
Product Dimensions- 1186mm(L) x 480mm(W) x 490mm(H)
Shipping Size48"x40"x32"
Shipping Weight320 lbs
VGB-1

Compact Stainless Steel Vacuum Glovebox with Automatic Pressure Controller – VGB-1-KJT

VGB-1-KJT is a small size stainless steel glove box with an  Antechamber, Gauges, and vacuum Flanges, which allows the glovebox to be vacuumed to remove moisture and oxygen without expensive inert gas purging. A pressure controller is integrated to automatically maintain the glovebox pressure at the set range. It is an ideal tool for material and chemical researchers to process air sensitive materials and solutions.

DesriptionSpecification
Power- Glovebox: N/A
- Pressure Controller: 110 - 220 VAC, 50/60 Hz
Glove Box Chamber- Case Material: Made of 11 gauge (3mm thickness) 304 stainless steel sheet with the support frame, which provides the heavy-duty structure for vacuum.
- Dimensions: 555 (L) × 444 (W) × 414 (H)
- Window: 480 (L) × 125 mm (H)
- Max. Positive Pressure: 810 Torr (1.1 atm)
- Note: Gloves cannot work if pressure is higher than 810 Torr
- Max. Vacuum Level: 1.59E-2 Torr
- ~50 Torr after 5 min pumping
- ~6E-2 Torr after 4 hr pumping.
- Note: Stainless Steel case may deform at a higher vacuum level
- Leakage Rate in GloveBox: < 6 Torr/hour 
- Overall Dimension Drawing   
 Section View Enlarging
Pressure Controller- EQ-KJT-2V Automatic Pressure Controller is integrated with the glovebox to maintain constant inert gas pressure inside the main chamber. 
- One pressure transducer and two solenoid valves are pre-installed in the back of the Main Chamber.
- Pressure Range:  90 - 320 kPa  with 0.5% accuracy.
- Pressure Controller must be power OFF when vacuum the Main Chamber.
Antechamber- Dimensions: 200mm(ID) x 220mm(L)
Vacuum gauge and valves- Two vacuum flanges are included for the glove box to achieve vacuum to remove moisture and oxygen without expensive inert gas purging.
- Do not operate under vacuum. Vacuum is used for purging the chamber before the operation.
- One KF-25 connector is installed on the back for connecting the humidity monitor or other testing equipment.
Power Extension- One outlet strip (Max power 1500W) with feedthrough is installed in the glove box main chamber.
- Note: 110V power cord was included for immediate use. (For 208~240V power supply, no plug will be included) 
Gloves- One pair of Latex Gloves are included for immediate use.
- Optional: You may order 6'' Butadyl® gloves here because they have:
- Increased stretching, bending ability, and tear strength
- High effectiveness when vaporized hydrogen peroxide (VHP) is present
- High resistance to aromatics, hydrocarbons, solvents, fats, and acids
- High static dissipative qualities   
Vacuum Pump- The vacuum pump and fittings are not included. (Please order separately under Personalization) 
(Optional)- Note: A KF25 Vacuum Right-Angle Valve is necessary for connecting to a vacuum pump, please order it accordingly.
Product Dimensions- 1186mm(L) x 480mm(W) x 490mm(H)
Shipping Size- 48"×40"×32"
Shipping Weight- 320 lbs
VGB-1-KJT_1-1

Benchtop Vacuum Glove Box (31″x 26″ x 28″) with Airlock and vacuum Flange & Gauge – VGB-3

VGB-3 is a middle size heavy-duty stainless steel glove box with  Airlock Chamber, Gauges and vacuum Flanges, which allows the glove box to vacuum the chamber to remove moisture and oxygen without expensive inert gas purging, It is an ideal tool for material and chemical researchers to process air sensitive materials and solutions.

DesriptionSpecification
Glove Box Chamber- Case Material: Made of 11 gauge (3mm thickness) 304 stainless steel sheet with support frame and plastic paint, which provide heavy duty structure for vacuum
- Dimensions: 780mm(L) x 700mm(W) x 650mm(H)
- Max. Positive Pressure: 810 Torr (1.1 atm) ( When close the flanges )
Max. Vacuum Level: 0.05 Torr
Note: Stainless Steel case may deform at higher vacuum level
Airlock Chamber- Dimensions: 240mm(ID) x 260mm(L)
- Max. Vacuum Level: 0.05 Torr 
Vacuum gauge and valves- Two vacuum flanges are included for glove box to achieve vacuum to remove moisture and oxygen without expensive inert gas purging
- Two KF-25 vacuum fitting ports with Quick Clamps are installed in the back for connecting vacuum pump, electric/fluid feed-through, gas circulating/purifying system, or other testing equipment
Leakage Rate in Glove Box - < 6 Torr/hour 
Power Extension- One extension socket (Max power 1500W) is installed in the glove box main chamber.
- Note: 110V power cord was included for immediate use. (For use under 208~240V power supply, no plug will be included) 
Gloves- One pair of Latex Gloves is included for immediate use
- Clamps and sealing flanges included
- Optional: You may order 6'' Butadyl® gloves here because they have:
- Increased stretching, bending ability, and tear strength
- High effectiveness when vaporized hydrogen peroxide (VHP) is present
- High resistance to aromatics, hydrocarbons, solvents, fats, and acids
- Resists ozone
- High static dissipative qualities
Vacuum pump and fittings (Optional)- The vacuum pump and fittings are not included. (Please click on the first picture below to order separately) 
- We may add a customized flange to connect a tube furnace to the glove box
- You may order pressure controller to keep inert gas pressure constant ( click Pic below right 2)
- We may order the glovebox with a gas purification system. ( click picture right to see specs )
- The humidity inside the glove box can be controlled by using either manual purging system or Gas Purification System. Please see our experimental results below:
- Humidity Range 4~5% Rh: Can be achieved after manually purging the system for 6 cycles by using N2 gas supply tank
- Humidity Range < 2% Rh: Please use either gas supply with 99.9999% gas purity with moisture filter or a Recirculating Gas Purification System for purging
Shipping Dimensions- 50" x 40" x 37" 
Shipping Weight- 240 kg (520 lbs)
VGB-3

Large Stainless Steel Vacuum Glove Box (Chamber Size: 44″x29″x35″) with Airlock Chamber – VGB-4A-LD

VGB-4A-LD is a heavy-duty stainless steel glove box equipped with airlock chamber, gauges, and vacuum flanges, which allows the glove box to vacuum the chamber to remove moisture and oxygen without expensive inert gas purging, It is an ideal tool for material and chemical researchers to process air sensitive materials and solutions.


DesriptionSpecification
Glove Box Chamber- Case Material: Made of 11 gauge (3mm thickness) 304 stainless steel sheet which provides the heavy-duty structure for vacuum
- Dimensions: 1120mm(L) x 740mm(W) x 900mm(H)
- Max. Positive Pressure: 810 Torr (1.1 atm)
- Note: Gloves cannot work if pressure is higher than 810 Torr
- Max. Vacuum Level: 0.5 Torr
- Note: Stainless Steel case may deform at higher vacuum level
Airlock Chamber with Air Lifting- Dimensions: 360mm(ID) x 435mm(L)
- Max. Vacuum Level: 0.05 Torr 
Transparent Front - Dimension: 1040mm(L) x 405mm(W)
- Removable for putting in devices
- 30mm thick plexiglass
Vacuum Gauge and Valves- One vacuum gauge is installed in the airlock chamber.
- 1 set of 1/2" barbed needle valve and 1 KF-25 Vacuum port built-in airlock chamber.
- 1 KF40 port and 2 1/2" barbed needle valves are built on the chamber side of the glove box.
- 2 sets KF25 ports are built on the back of the glove box chamber.
- 3 sets KF40 ports are built on the back of the glove box chamber for connecting to the gas purification system.
Leakage Rate in Glove Box - < 3 Torr/hour
Power Extension- One extension socket (Max power 1500W) is installed in the glove box main chamber
- Note: 110V power cord was included. (For use with 208~240V power supply, no plug will be included.) 
Gloves- Glove port size: 190mm in diameter.
- One pair of 8" Latex Gloves are included for immediate use.
- Optional: You may order a pair of 8'' Butadyl® Gloves  (with increased stretching, bending ability and tear strength, and offer strong resistance to aromatics, hydrocarbons, solvents, fats, and acids)
- Clamps and sealing flanges included.
VGB42.1

Glove Box with Hinged Front Window w/o Purification- VGB-5

VGB-5 is a stainless steel glove box with the hinged type of front door designed for much easy loading and unloading device into the glove-box. It is designed for handling flammable material and devices under inert gas without a purification system.  

DesriptionSpecification
Glove Box Chamber- Case Material: Stainless steel 304 with 3 mm thickness
- Chamber dimension: 1200 mm L x 740 mm W x 900 mm H
- Openable front window panel (tempered glass, 8 mm thick)
- A power plug is included inside the chamber
- Three KF40 port for feeding electronic devices
- Note:  the chamber oxygen level may reach < 100 ppm  via multi-time purging via 5N inert gas
Leak Rate- <0.05 vol% / hr (depending on oxygen concentration inside the glove box)
Airlock Chamber- Antechamber dimension: 360 mm Dia. x 600 mm L
- Small chamber dimension (for tools): 150 mm Dia. x 220 mm L
- KF25 port is included to connect vacuum pump  and gas inlet and outlet valves are built in the antechamber
Working Gas- Operating gas: Inert gas such as N2, Ar, He
- Regenerating gas: For regenerating both oxygen and H2O remover, use a mixture of H2 (5-10%) and operating gas 
Ports & Fittings- Total three KF40 ports on the back of the glove box
Pressure Control System- Automatic pressure control by PLC for the Glove Box Chamber
- Pressure range: 12 m-bar Max.
- Manually control the pressure 
Gloves- A pair of 9 3/4" butyl glove is included for immediate use
Optional- You may need a vacuum pump with filter is included for a faster vacuum of antechamber (Pic. 1 )
- Stainless steel vacuum bellow and valve are required ( KF25 )
- You may order a pressure control unit to keep constant chamber pressure at the extra cost (Pic. 2)
Dimension- Product Dimension: 2000 mm L x 1000 mm W x 1880 mm H (79" x 40" x 74")
- See the pictures below for detailed dimensions
Shipping Dimension- 86" L x 45" W x 91" H
Shipping Weight- 640 kg (1400 lbs)
Compliance- No electricity involved, NRTL is not required
VGB-6-LD

Dry Glove Box with Humidity Purification System (H2O < 1 ppm) for Li-Ion Battery Research – VGB-7H2-LD

VGB-7H2 is a dry glove box  with automatic moisture purification system, which can provide a dry gas environment with moisture lower than 1 ppm . It is a cost-effective solution for Li-Ion battery research at low cost because most Li-ion battery’s electrolyte is sensitive to moisture, but not oxygen. One slidable Sample Shelf is built on top inside glovebox to make operation easy.

DesriptionSpecification
Working Voltage- 220V 50/60Hz, Single Phase (110V AC is available at extra cost)
Glove Box Chamber &- Case Material: Made of  304 stainless steel sheet 
Airlock Chamber- Dimensions: 1200 mm(L) x 740mm(W) x 900mm(H)
- Total Height with frame:  1880 mm
- Max. Positive Pressure: 810 Torr (flowing gas only, not designed for vacuum)
- Airlock Chamber with Airlift
- Dimensions: 360mm(ID) x 600mm(L)
- Max. Vacuum Level: 0.05 Torr 
- Two 175mm diameter glove port with a pair of  6'' Butadyl® gloves
- One slidable Sample Shelf is built on top inside glovebox to make operation at easy
- The LED light is the built-in outside glove box
- Glove Port size: 190mm(Dia.)
- 8'' Butadyl® Gloves included (with increased stretching, bending ability and tear strength, and offer strong resistance to aromatics, hydrocarbons, solvents, fats, and acids)
- Clamps and sealing flanges included
Transparent Front Panel- Front Panel made of transparent plastic 
- Dimension: 1200 mm(L) x 700mm(W)
- Removable for putting in devices
Purification System- Automatic moisture remove to < 2 ppm (Li-Ion battery assembling requires <11 ppm moisture)
- Precision Humidity Analyzer with KF25 Flange (0-999 ppm) is installed on the Purification System with accuracy  +/-0.1 ppm
- Large capacity moisture filter built-in bottom of a mobile cart, which can soak moisture up to 1.5kg
- Oxygen will be removed during operation but not to be measured.
- Regeneration Temperature Controller is built-in for automatically regenerating the filter
- The automatic pressure control system is built in to keep the pressure at a constant level
- 6" color PLC touch panel is included which can set and display the humidity and pressure level. (Please click the first picture below for details)
- The control panel is removable, which can be placed anywhere for easy operation          
Purification Pipeline- 304 stainless steel, KF40 port
Vacuum pump- Heavy-duty vacuum pump with filter is included for faster vacuum and removing moisture
- Stainless steel vacuum bellow and valve are included
Gasses Requirement- Working gasses: Atmospheric Gases, N2, Argon          
- Regeneration Gas: 95% N2 + 5%H2
- One float meter built on the front of a mobile cart for accurate gas filling
Power Extension- One extension socket (Max power 1500W) is installed in the glove box main chamber
- The power cord was included (For use with 208~240V power supply, no plug will be included) 
Dimensions for Glove Box- Glovebox:  1230mm L × 2000mm W × 1880mm H ( click picture below to see the detail size 
and options- Tube furnace with bottom loading or melt spinner may connect to the glovebox is upon request
VGB-7H2-LD

Glove Box with H2O & O2 Purification System and Hinged Front Window – VGB-6-LD

VGB-6-LD is a stainless steel glove box with the hinged type of front door designed for much easy loading and unloading device into the glove-box. The purification cylinder is made of BASF R3-11 Copper Catalyst and Lindy Molecular Sieve in order to achieve a low water and oxygen concentration of  lower than 1 ppm, such that experiments can be conducted in an ultra-clean and highly purified gas environment. It is integrated with a vapor pressure control system, purity control system, automatic gas purity regeneration control system, and system data log recording. EQ-VGB-6 is widely used in preparing nanomaterials, Li-ion battery materials, catalysts, and metallorganics. 

DesriptionSpecification
Working Voltage- 110 or 220 VAC switchable, 50/60 Hz, single phase
- Max power: 1.5 kW 
Glove Box Chamber- Case Material: Stainless steel 304 with 3 mm thickness
- Chamber dimension: 1200 mm L x 740 mm W x 900 mm H
- Openable front window panel (tempered glass, 8 mm thick)
Chamber Condition- Regeneration Temperature Controller is built-in for automatically regenerating the filters
- Automatically purging function is built-in for quick reducing O2 < 200ppm & H2O < 50 ppm before recycling.
- The automatic pressure control system is built in to keep the pressure at a constant level.
- Water concentration: <1 ppm (20 °C, 1 atm)
Oxygen concentration: <1 ppm (20 °C, 1 atm)
    Leak Rate- <0.05 vol% / hr (depending on oxygen concentration inside the glove box)
Airlock Chamber- Antechamber dimension: 360 mm Dia. x 600 mm L
- Small chamber dimension (for tools): 150 mm Dia. x 220 mm L
Optional vacuum jar- Loading and unloading device from the front door is much easier than ever!     Vacuum sealed jar is available for air-sensitive  sample transporting
Working Gas- Operating gas: Inert gas such as N2, Ar, He
- Regenerating gas: For regenerating both oxygen and H2O remover, use a mixture of H2 (5-10%) and operating gas 
Gas Purification System- Automated regeneration process
- Automated Water and oxygen removal
- Purification cylinder: made of BASF R3-11 Copper Catalyst and Lindy Molecular Sieve
- Pipeline: 304 stainless steel, KF40, and KF25 ports
Ports & Fittings- Total three KF40 ports on the back of the glove box
Filter System- Inlet and outlet filter can eliminate particle size > 0.3 μm
- Carbon and solvent vapor filters are available upon request at the extra cost for flammable vapor
Pressure Control System- Automatic pressure control by PLC for the Glove Box Chamber
- Pressure range: +/- 12 mbar
- Manual pressure control is allowed via a foot pedal
Purging System- Automatic purging system allows easy operating and reduces gas consumption
Control System- Siemens PLC control system with 7" touchscreen display
- Water concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
- Oxygen concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
- Pressure: -12 to 12 mbar with an accuracy of 0.01 mbar
- Records for total hours of operation, total regeneration times, time since last regeneration
Pump- 240 L/m heavy duty double stage rotary vane pump for faster gas exhaust
Vacuum rate: 240 L/m (8.5 cfm)
GlovesA pair of 9 3/4" butyl glove is included for immediate use
LightingBuilt-in fluorescent lamp
Dimension- Product Dimension: 2000 mm L x 1000 mm W x 1880 mm H (79" x 40" x 74")
- See the pictures below for detailed dimensions
VGB-6-LD

Dual Chamber Glove Box with Gas Purification System (H2O & O2< 1ppm) – VGB-6-II-LD

VGB-6-II-LD is a dual stainless steel glove box designed for researchers in material science, chemistry, semiconductor, and related topics. The purification cylinder is made of BASF antioxidant materials from Germany and UOP water adsorbent materials from the US in order to achieve a low water and oxygen concentration of  lower than 1ppm, such that experiments can be conducted in an ultra-clean and highly purified gas environment. It is integrated with vapor pressure control system, gas purification system, automatic gas regeneration control system, auto alarm, and system data log recording VGB-6-II is widely used in preparing nanomaterials, Li-ion battery materials, catalysts, and metallorganics. 

DesriptionSpecification
Working Voltage- 110VAC or 220VAC, 50/60Hz, Single Phase
Max. Power Consumption- 1.7KW
Glovebox Chamber- Fully openable front window panel (tempered glass, 8 mm thick)
- Dimensions: 2400mm(L) x 800mm(W) x 930mm(H)
- Case Material: Stainless Steel 304
- Built-in fluorescent lamp
- Two shelves, 300mm L x 250mm W x 300mm H
- Two pieces of HEPA filters for particle size >0.3 μm
Antechambers- Large Antechamber Dimensions: 360mm(Dia.) x 600mm(L)
- Small Antechamber Dimensions (for tools): 150mm(Dia.) x 300mm(L)
- Max. vacuum level: 100 Pa
Obtainable Purity Level- Water concentration: <1 ppm (20°C, 1 atm)
- Oxygen concentration: <1 ppm (20°C, 1 atm)
Working Gas- Operating gas: Inert gas such as N2, Ar, He
- Regenerating gas: Mixture of H2 (5%) and Operating gas
- Note: If you use Ar gas, please make sure the inside equipment is Ar gas compatible
Gas Purification System- Auto regeneration process with user defined parameters.
- Built-in Regeneration Temperature Controller.
- Automatically purging function is built-in for quickly reducing O2 < 100ppm & H2O < 100 ppm before cycling.
- The automatic pressure control system is built in to keep the pressure at a constant level.
- Purification Cylinder: made of BASF antioxidant materials (Na86((AlO2)86(SiO2)106.XH20, 5 kg) and UOP water adsorbent materials.
- Moisture removal capacity: 2 kg
- Oxygen removal capacity:   60L
- Stainless steel pipe connection
- Blower: Flow Rate: 90m³/h
Filter System (optional)- One Organic Solvent Filter System filled with replaceable activated carbon (5.2kg) is optional
- Carbon and solvent vapor filters are available upon request at the extra cost for flammable vapor 
    Control system- Siemens PLC control system with 6" touchscreen display
- Water concentration: 0 - 1000 ppm 
- Oxygen concentration: 0 - 1000 ppm
- Auto pressure control -5 - 8 mbar
Feedthroughs- Power feedthrough is included.
- power extension board with 5 outlets, 15A max. 
- Can be 110VAC or 220VAC depending on the input source
Vacuum Pump- 240L/m Heavy Duty Double Stage Rotary Vane Pump for faster gas exhaust
- Vacuum rate: 7.8 cfm
- Lowest pressure: 0.4pa
Gloves- Two pairs of NORTH Butyl glove is included
- Protection against toxic materials
- 8" Dia.x 32" Long
Product Dimensions- 3235mm(L) x 1040mm(W) x 1860mm(H) (127" x 41" x 73")
Heatable Antechamber (optional) - Heatable Antechamber: 200C max., DN385×588mm (L), available
- Two large ante-chambers, one right and one left, is available upon request
Shipping Dimensions & Weight- 2 pallets, 1800 lb total weight     #1: 86"x41"x84"     #2: 86"x41"x83"
VGB-6-II-LD

Triple Chambers Glove Box with Gas Purification System (H2O&O2< 1ppm) – VGB-6-III-LD

VGB-6-III-LD is a triple stainless steel glove box with one middle openable front window designed for researchers in material science, chemistry, semiconductor, and related topics. The purification cylinder is made of BASF antioxidant materials from Germany and UOP water adsorbent materials from the US in order to achieve a low water and oxygen concentration of  lower than 1ppm, such that experiments can be conducted in an ultra-clean and highly purified gas environment. It is integrated with a vapor pressure control system, purity control system, automatic gas purity regeneration control system, auto alarm, and system data log recording.   Three slidable shelves are built in the glovebox to make operation at easy. VGB-11 is widely used in preparing nanomaterials, Li-ion battery materials, catalysts, and metallorganics. 

DesriptionSpecification
Working Voltage- 220V AC, 50/60Hz, Single Phase
Max. Power Consumption- 4KW
Glove Box Chamber- Case Material: Stainless Steel 304
- Dimensions: 3600mm(L) x 800mm(W) x 930mm(H)
- 12mm thick double layer laminated safety glass with corrosion protection film for operating in a safe and easy manner
- Ample space for cell fabrication line.
Chamber Condition- Water concentration: <1 ppm (20°C, 1 atm)
- Oxygen concentration: <1 ppm (20°C, 1 atm)
- Leak rate: <0.05 Vol% / hr (Depending on oxygen concentration inside the glove box)
- Antechamber Dimensions: 385mm(Dia.) x 588mm(L)
Air-lock Chamber- Small Chamber Dimensions (for tools): 150mm(Dia.) x 300mm(L)
- Max. vacuum level: 100 Pa
Working Gas- Operating gas: Inert gas such as N2, Ar, He
- Regenerating gas: Mixture of H2 (5%) and Operating gas 
- For purification system with only water adsorbing function, Regenerating gas will be the same as Operating gas
Filter System- Organic Solvent Filter System filled with replaceable activated carbon
- Built-in HEPA filter can eliminate particle size > 0.3μm
Control system- Siemens PLC control system with 6" touchscreen display
- Water concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
- Oxygen concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
- Pressure: -2500 to 2500 Pa with an accuracy of 1 Pa
- Purification limitation:
- Water concentration: <1 ppm (20°C, 1 atm)
- Oxygen concentration: <1 ppm (20°C, 1 atm)
- Regeneration Temperature Controller is built-in for automatically regenerating the filters
- Automatically purging function is built-in for quick reducing O2 < 200ppm & H2O < 50 ppm before recycling.
- The automatic pressure control system is built in to keep the pressure at a constant level.
Pump- 240L/m Heavy Duty Double Stage Rotary Vane Pump for faster gas exhaust
- Vacuum rate: 7.8 cfm
- Lowest pressure: 0.4pa
Blower- Flow Rate: 90m³/h
Purification Pipeline- 304 Stainless Steel, KF40 Port
Gloves- A pair of NORTH Butyl glove is included to provide better protection against toxic materials
Lighting- Built-in fluorescent lamp
Slidable Shelf- Two slidable shelves are built-in top of inside glove chamber with dimensions of 300mm x 250mm
- 300mm away from the roof
Product Dimensions- 4200mm(L) x 830mm(W) x 1830mm(H) (165" x 33" x 72")
Optional - Heatable Antechamber: 200C max., DN385×588mm (L),  (Pic.1-2)
- Two large Ante-chamber is available  (Pic. 3)
- 5" tube furnace with bottom loading is available on one of top glovebox for oxygen-free sintering (Pic. 4)
VGB-6-III-LD

Four Chambers Glove Box with Gas Purification System ( H2O&O2 < 1ppm) – VGB-6-IV-LD

VTC-50H is a mini spin coater with a vacuum chuck that is designed for quality coating inside the glovebox at a low cost. It can be easily set up and use at a speed of 500 – 8000 r/min. A heating cover and temperature controller are included for fast heating up to 80°C.    8″ diameter or 5″ x 5″ square. The spinning speed is variable from 500-6000 rpm with two programmable segments. The heata”>The mini spin coater is Ar gas compatible can be put in a glovebox through antechamber


DesriptionSpecification
Working Voltage- AC 220V 50/60 Hz Single Phase
Max Power Consumption- 5 KW
Glove Box Chamber- Material: Stainless Steel 304
- Dimensions: 4800 mm (L) x 800 mm (W) x 930 mm (H)
- 12 mm thick double layer laminated safety glass with corrosion protection film for operating in a safe and easy manner
- Ample space for the cell fabrication line
Chamber Condition- Water concentration: < 1 ppm (20°C, 1 atm)
- Oxygen concentration: < 1 ppm (20°C, 1 atm)
Leak Rate- <0.05 Vol% / hr (Depending on oxygen concentration inside the glove box)
Airlock Chamber- Two Antechambers and two small chambers on both sides of the glove box
- Antechamber Dimension: 385 mm (Dia.) x 588 mm (L)
- Small Chamber Dimension: 150 mm (Dia.) x 300 mm (L)
- Maximum vacuum level: 100 Pa 
Working Gas- Operating gas: Inert gas such as N2, Ar, He
- Regeneration gas: Mixture of H2(5%) and Operating gas
- For purification system with only water adsorbing function, Regenerating gas would be the same as Operating gas
Filter System- Two Purification Cylinders included due to the large glove box
- Organic Solvent Filter System filled with replaceable activated carbon
- Built in HEPA filter can eliminate particle size > 0.3μm
Control System- Siemens PLC control system with 6" touchscreen display
- Water concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
- Oxygen concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
- Pressure: -2500 to 2500 Pa with an accuracy of 1Pa
- Purification limitation
- Water concentration:  <1 ppm (20°C, 1 atm)
- Oxygen concentration: <1 ppm (20°C, 1 atm)
Pump- 240 L/m Heavy Duty Double Stage Rotary Vane Pump for the gas exhaust
- Vacuum rate: 7.8 CFM
- Lowest pressure: 04 Pa
Blower- Flow Rate: 90m³/h
Purification Pipeline- 304 Stainless Steel, KF40 Port
Gloves- A pair of NORTH Butyl glove is included to provide better protection against toxic materials for one chamber
- Four pairs in total
Lighting- Built-in fluorescent lamp
Slidable Shelf- Four slidable shelves are built on top of inside glove chamber with dimensions of 300mm x 250mm
- 300 mm away from the roof
Optional- Universal terminal panel is a convenient part with varies feedthrough built-in for VGB series glove boxes to transfer gas/vacuum pipelines, circuit cables, etc.
- Dimensions: 420x280mm
- Adapter: 10 Φ6 ports, 4 Φ8 ports, 4 Φ12 ports
- Heatable Antechamber: 200C max., DN385×588mm (L), extra cost $7699
Product Dimensions- 6500mm(L) x 830mm(W) x 1830mm(H) (256" x 33" x 72")
VGB12.2.1

Five Chambers Glove Box with Gas Purification System ( H2O&O2 < 1ppm) – VGB-6-V-LD

VGB-6-V-LD is a five stainless steel glove box with one middle openable front windows designed for the Lithium-Sulfur & Lithium-Metal battery research in one glove box. The purification cylinder is made of BASF antioxidant materials from Germany and UOP water adsorbent materials from the US, in order to achieve a low water and oxygen concentration of lower than 1 ppm, such as the experiments, can be conducted in an ultra-clean and highly purified gas environment. It is integrated with the vapor pressure control system, purify control system, automatic gas purity regeneration control system, auto alarm, and system data log recording.  Five slidable shelves are built in the glove box to make operations easier. VGB-6-V-LD is perfectly fit for Lithium-sulfur and lithium metal battery research.

DesriptionSpecification
Working Voltage- AC 220V 50/60 Hz Single Phase
Max Power Consumption- 6 KW
Glove Box Chamber- Material: Stainless Steel 304
- Dimensions: 6,000 mm (L) x 800 mm (W) x 930 mm (H)
- 12 mm thick double layer laminated safety glass with corrosion protection film for operating in a safe and easy manner
- Ample space for the cell fabrication line
Chamber Condition- Water concentration: < 1 ppm (20°C, 1 atm)
- Oxygen concentration: < 1 ppm (20°C, 1 atm)
Leak Rate- <0.05 Vol% / hr (Depending on oxygen concentration inside the glove box)
Airlock Chamber- Two Antechambers and two small chambers on both sides of the glove box
- Antechamber Dimension: 385 mm (Dia.) x 588 mm (L)
- Small Chamber Dimension: 150 mm (Dia.) x 300 mm (L)
- Maximum vacuum level: 100 Pa 
Working Gas- Operating gas: Inert gas such as N2, Ar, He
- Regeneration gas: Mixture of H2(5%) and Operating gas
- For purification system with only water adsorbing function, Regenerating gas would be the same as Operating gas
Filter System- Two Purification Cylinders included due to the large glove box
- Organic Solvent Filter System filled with replaceable activated carbon
- Built-in HEPA filter can eliminate particle size > 0.3μm
Control System- Siemens PLC control system with 6" touchscreen display
- Water concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
- Oxygen concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
- Pressure: -2500 to 2500 Pa with an accuracy of 1Pa
- Purification limitation
- Water concentration:  <1 ppm (20°C, 1 atm)
- Oxygen concentration: <1 ppm (20°C, 1 atm)
- Regeneration Temperature Controller is built-in for automatically regenerating the filters
- Automatically purging function is built-in for quick reducing O2 < 200ppm & H2O < 50 ppm before recycling.
- The automatic pressure control system is built in to keep the pressure at a constant level.
Pump- 240 L/m Heavy Duty Double Stage Rotary Vane Pump for the gas exhaust
- Vacuum rate: 7.8 CFM
- Lowest pressure: 04 Pa
Blower- Flow Rate: 90m³/h
Purification Pipeline- 304 Stainless Steel, KF40 Port
Gloves- A pair of NORTH Butyl glove is included to provide better protection against toxic materials for one chamber
- Four pairs in total
Lighting- Built-in fluorescent lamp
Slidable Shelf- Five slidable shelves are built on top of inside glove chamber with dimensions of 300mm x 250mm
- 300 mm away from the roof
Separating Door (optional)- The separating door is designed to separate the chamber when the accident happens, and let other chambers keep running.
- The shutter doors shown are in the chamber 2nd and 4th.
Optional- The universal terminal panel is a convenient part with various feedthrough built-in for VGB series glove boxes to transfer gas/vacuum pipelines, circuit cables, etc. ( Pic. 1-2)
- Dimensions: 420x280mm
- Adapter: 10 Φ6 ports, 4 Φ8 ports, 4 Φ12 ports
- Heatable Antechamber: 200C max., DN385×588mm (L), extra cost $7699
- The extra purification system is available to avoid accidents happen.
- Carbon filtering and sloven vaper filtering systems are available upon request. (Pic. 6)
Product Dimensions- 7598mm(L) x 830mm(W) x 1830mm(H) (300" x 33" x 72")
VGB-6-V-LD

Small Drying Room (100 SF) with Air Shower and self-cleaning Tunnel – MSK-ADR-1500EP40-LD

MSK-ADR-1500EP40 is a small walking dry room with 9 square meters ( 100 SF) area and dew point < -40ºC. The new two-stage moisture removing technology is applied to the small dry room. For instance, the refrigeration system is at first stage and multi-molecular sieve purification column is at the second stage.The technology could remove moisture quietly and save power compared to the conventional dry room. The dry room allows the operator walking in the chamber to work efficiently compared to the glove boxes.The 9 square meters area dry room is equivalent to 10 sets of standard glove boxes but at the about 50% cost.The walk-in dry room is perfectly designed for the Li-ion battery pilot line.

DesriptionSpecification
Features and principle- Modular design for easy installation without professionals
- Made of stainless steel plate with 3 mm thickness
- Uniformly remove moisture without "dead corner " and "channel effect"
- Dew Point can reach -40ºC
- Power saving with quiet operation
- Only allow one person to operate inside the dry room
 Dry Room Dimension- Internal  Area: ~ 9 square meters ( 96.8 square feet )
- Operation Area: 2,600 mm L x 2,600 mm W x 2,200 mm H
- Dry room size: 3,000 mm L  x 3,000 mm W  x 3,000 mm H
- Dehumidification system size: 2,000 mm L x 1,000 mm W x 2,000 mm H
- Lighting and power cords are built inside the dry room
Power requirement- AC 220 V +/- 10%, 50 / 60Hz, Three phases
- 10 KW Max.
- Normal energy consumption for continuous operation:  7 kW
Water Cooling Requirement- < 7 Celcius degree cooling water
Shower- Preinstalled in the front of the door 
- Single person walk-in
- 10 - 99 second cleaning time adjustable
Control System- Purification limitation: Water concentration -40ºC Dew Point with the empty room
Air Flow- 1,500 CMH (cubic meter per hour)
- 882 CFM (cubic feet per minute)
Air Turn Over- 20 times per hour
MSK-ADR-1500EP40-LD

Automatic Recirculating Gas Purification System (O2 & H2O < 1 ppm) For Glovebox- EQ-RMP-LD

EQ-RMP-1 is an automatic recirculating moisture and oxygen purification system, which can provide an environment with moisture and oxygen concentration lower than  1 ppm for the standard glove box.

DesriptionSpecification
Working Voltage- 20V 50/60Hz, Single Phase (110V version is available at extra cost)
- 1500W Max.
Purification System- Precision oxygen sensor and humidity sensor ar built-in
- Automatically purging function is built-in for quick reducing O2 < 100ppm & H2O < 100 ppm before recycling.
- The automatic pressure control system is built in to keep the pressure at a constant level.
- Purification Cylinder: made of BASF antioxidant materials and UOP water adsorbent materials.
- Purification ratings: O2 < 1ppm & H2O < 1 ppm
- Moisture removal capacity: 2 kg
- Oxygen removal capacity:   60L
- Stainless steel pipe connection
- Flow Rate: 1-60m³/h
- Auto regeneration process with user-defined parameters.
- 6" color PLC touch panel is included which can set and display the oxygen, humidity, and pressure level
- Purification with a humidity sensor or oxygen sensor is possible to save the cost.
- Note: when oxygen reaches 1 PPM, H2O also reaches < 1 ppm for sure. choose O2 sensor only can save ~$2000
- The organic solvent filter can be added upon request at the extra cost 
Purification Pipeline- Two 304 stainless steel KF40 ports for inert gas inlet/outlet recirculation through the filter
- One heavy-duty vacuum pump, 240L/m is included in this system: EQ-YTP-550 
- Note: You need to order two sets of 1000mm length SS Bellows: KF-40 to the KF-25 Reducer Union, KF-40 & KF-25 quick clamp to connect the purification system to MTI's VGB-3 or VGB-4A glove box. KF-40 to the KF-25 Reducer Union are available at extra cost (Please click on the third picture below for details)
Working gases- Working gases: Helium, Nitrogen, Argon
- Regeneration Gas: 95% N2 + 5% H2 gas
- One flow meter is included for accurate gas filling
EQ-RMP-LD

Automatic Recirculating Gas Purification System (O2 < 1 ppm) With Temperature Control System- RMP-2F-LD

RMP-O2 is an automatic recirculating oxygen purification system with a touch screen temperature control panel, which can provide an environment with oxygen concentration lower than  1 ppm for MTI’s tube furnace. The gas purification system can replace expensive (10-6 torr) turbopump vacuum systems to achieve better oxygen-free conditions for crystal growth, CVD furnaces, and Ti alloy annealing furnace, etc.

DesriptionSpecification
Working Voltage- 20V 50/60Hz, Single Phase (110V version is available at extra cost)
1500W Max.
Purification System- Precision oxygen is built-in ( without humidity sensor )
- Automatically purging function is built-in for quick reducing O2 < 100ppm before recycling.
- The automatic pressure control system is built in to keep the pressure at a constant level.
- Purification Cylinder: made of BASF antioxidant materials and UOP water adsorbent materials.
- Purification ratings: O2 < 1ppm  ( H2O < 1 ppm will reach <1 ppm when oxygen < 1 ppm)
- Moisture removal capacity: 2 kg
- Oxygen removal capacity:   60L
- Stainless steel pipe connection
- Flow Rate: 1-60m³/h
- Auto regeneration process with user-defined parameters.
- 6" color PLC touch panel is included which can set and display the oxygen and pressure level, and temperature control programma.
Purification Pipeline- Two 304 stainless steel KF40 ports for inert gas inlet/outlet recirculation through the filter
- One heavy-duty vacuum pump, 156L/m is included in this system: EQ-FYP-Pump
- Note: You need to order two sets of 1000mm length SS Bellows: KF-40 to the KF-25 Reducer Union, KF-40 & KF-25 quick clamp to connect the purification system to MTI's VGB-3 or VGB-4A glove box. KF-40 to the KF-25 Reducer Union are available at extra cost (Please click on the third picture below for details)
Working gases- Working gases: Helium, Nitrogen, Argon
- Regeneration Gas: 95% N2 + 5% H2 gas
- One flow meter is included for accurate gas filling
Communication with MTI furnaces- The purification system has a build-in connection port to the MTI furnace. 
- Control and monitor furnace status can be set over the touchscreen.
RMP-2F-LD